Home About Us Contact Us Purchase NW600 Dispensers Disinfecting Wipe Refills FAQ Site Map

 

DIRECTIONS FOR USE
It is a violation of Federal Law to use this product in a manner inconsistent with its labeling.
This product is not for use on critical and semi-critical medical device surfaces.

CLEANING: Use one FULL SPECTRUM DISINFECTANT wipe too completely remove surface of all gross debris from surfaces to be treated.

DISINFECTING: To disinfect hard, non-porous surfaces, thoroughly wet the surface to be treated.
Treated surface must remain visibly wet for disinfection:
" To disinfect against Escherichia coli (E. coli), Esherichia coli O157:H7, Pseudomonas aeruginosa, Salmonella choleraesuis and Vancomycin Resistant Enterococcus (VRE), Staphylococcus aureus, Methicillin Resistant Staphylococcus aureus (MRSA), Mycobacterium bovis BCG (Tuberculosis)
and Vancomycin intermediate Resistant Staphylococcus aureus (VISA) allow the treated surface to remain wet for 10 minutes. A potable water rinse is required for surfaces in direct contact with food. For plastic and painted surfaces, spot test on an inconspicuous area before use. For heavily soiled surfaces, clean before following disinfecting instructions.


*VIRUCIDAL ACTIVITY: FULL SPECTRUM DISINFECTANT WIPES is an effective virucide on hard, non-porous surfaces against: " Human Immunodeficiency Virus Type 1 (HIV-1) when the treated surface is allowed to remain wet for 2 minutes. " Norovirus (Norwalk Virus) and Feline calicivirus when the treated surface is allowed to remain wet for 10 minutes. Use additional wipes if needed to assure that the treated surface remains continuously wet for the prescribed time.
For Ultrasound Transducers and Probes:
Use only on external surfaces of ultrasound transducers and probes. With a clean washcloth, clean gel from external surface of the ultrasound transducer or probe to be disinfected. Then thoroughly wet probe with wipe. Treated surface must remain wet for 10 minutes. Use additional wipes if needed to assure continuous 10 minute wet contact time. Let air dry.

KILLS HIV-1 ON PRE-CLEANED ENVIRONMENTAL SURFACES/OBJECTS PREVIOUSLY
SOILED WITH BLOOD/BODY FLUIDS

in health care settings (Hospitals, Nursing Homes) or other settings in which there is an expected likelihood of soiling of inanimate surfaces/objects with blood or body fluids, and in which the surfaces/objects likely to be soiled with blood or body fluids can be associated with the potential for transmission of Human Immunodeficiency Virus Type 1 (HIV-1) (associated with AIDS).

SPECIAL INSTRUCTIONS FOR CLEANING AND DECONTAMINATION AGAINST HIV-1 ON SURFACES/OBJECTS SOILED WITH BLOOD/BODY FLUIDS. PERSONAL PROTECTION:
When handling items soiled with blood or body fluids use disposable latex gloves, gowns, masks, or eye coverings.


CLEANING PROCEDURES: Blood and other body fluids must be thoroughly cleaned from surfacesand objects before application of this product. FULL SPECTRUM DISINFECTANT WIPES can be used for this purpose.

CONTACT TIME:
Thoroughly wet surface with a new FULL SPECTRUM DISINFECTANT WIPES.
Allow surface to air dry. Although efficacy at a 2 minute contact time has been shown to be adequate against HIV-1, use the recommended contact time for the disinfection of other organisms listed on this label.

DISPOSAL OF INFECTIOUS MATERIALS: Blood and other body fluids should be autoclaved and disposed of according to local regulations for infectious waste disposal.
Not for personal cleansing. This is not a baby wipe! Do not flush in toilet.

STORAGE AND DISPOSAL
Do not contaminate water, food or feed by storage or disposal.
ren.

Home About Us Contact Us Purchase NW600 Dispensers Disinfecting Wipe Refills FAQ Site Map